Shopping Cart
(0 Items)
My Account
(log in)

Cytek Launches new Website

Cytek launches new company website. [View...]


News articles can be viewed in their entirety in the News section of the site.


Customer Care   

For current telephone contact information, E-mail support and address information, visit our Customer Support page.

96-Well Automated Mico-Sampler (AMS)

Front View of AMS
Front View of AMS

Cytek's 96-well AMS provides rapid and reliable sampling from 96-well microtiter trays. Individual wells are pressurized to deliver the sample directly into the cytometer. Since the well is positioned directly below the cytometer's uptake tube, the transfer volume is less than 10ul, and transfer time is less than 2 seconds. This means lower carryover, and higher productivity for your lab. An innovative software package, AMS Integrated, controls Cellquestand Excel to provide superior data management capability. Now you can measure the absolute count of samples in your microtiter trays with our Absolute Count option. The sample is run through a precision volume to determine the events in a known volume, without using syringes. The count is recorded in the Cellquest data file, and can be exported to an Excel spreadsheet, along with the percent of events in the gate. CV's are less than 5% at 1,000/ul. For more information see our AMS brochure.

Compatible with FACScan, FACSort, LSR, and FACSCalibur Flow Cytometers. Compatible with Macintosh 7000 Series, G3 and G4 Computers running Cellquest.

AMS Robotic Plate Loader option

Robitic Plate loader
Robitic Plate loader

Use our PlateCrane to load up to 30 plates onto our 96-well autosamapler. The plate crane has the following features:

  • Stack up-to 30 plates: acquire 2880 samples in approximately 22 hours
  • Directly controlled by AMS software
  • All support hardware included




Time Zero calcium Flux Measurement system

Time Zero system
Time Zero system

Simulated kinetics experiment using non-fluorescent beads for cells and fluorescent beads for stimulus. Stimulus injection and boost begin at 4.4 seconds. "Stimulus" appears at laser intercept at 5.0 seconds, boost ends at 5.2 seconds. Time marks shown as vertical white lines at start and end of boost.

Probe the kinetics of cellular responses to drugs, ligands, and mitogens with the Time Zero System. This system provides on-line stimulus delivery to cells, then delivers activated cells to the laser intercept for analysis within a second. The Time Zero Air Supply provides adjustable run and boost pressures.

The Time Zero is compatible with FACStar, FACStar Plus, EPICs, Elites, and FACSVantage. With the Time Zero Air Supply, the Time Zero System is compatible with FACScan, FACSort, FACSCalibur, and LSR.


Item thumbnail

Features- Benefits:

  • Adjustable Sample Boost Time- Extends analysis to early activation kinetics
  • Sample water jacket- Defined temperature response
  • Sample/Stimulus Mixing- Uniform time zero
  • Time Zero electronic time- marks accurate time zero of stimulus activation
  • Sample Line pinch valve- no sample dilution from back flush
  • Uses standard disposable test tube- Low cost

Aerosol Containment System for FACSVantage SE

Aerosol Containment sysmet installed
Aerosol Containment sysmet installed

The system consists of two assemblies; a containment chamber that fits on the sorter, and a HEPA filter canister/fan unit that mounts in the lab or in a utility plenum above the lab. The two units are connected by flexible tubing, and the exhaust from the fan/filter unit is either connected to the exterior of the building, directly into the utility plenum, or into the lab. This system is defined as a Class 1 containment system, and prevents aerosols from escaping from the cytometer into the lab area.

The aerosol containment performance of a system with similar air flow characteristics has been tested by Simon Monard at the Trudeau Institute. No plaques were found outside the chamber when sorting high concentrations of phage. See the ACS details for more detail information on system and replacement parts.

Fluid Management system

Fluid management system
Fluid management system

Forget about filling the sheath tank on your flow cytometer. This system automatically pumps sheath fluid from a standard 20 liter supply cubitainer to your flow cytometer. It also automatically pumps waste fluid to a waste receptacle, or to any drain within 20 feet of your cytometer. The cytometer runs over 20 hours between cubitainers, a 5 fold increase in running time.

Our Ultra-Stable version for 4 color FACSCalibur� systems minimizes the need for performing time-delay calibrations. The system presently works with FACScan�, FACSort�, FACSCalibur� and LSR II cytometers.




© 2007 Cytek Development, Inc.
Site design by the Charlottesville Media Group